Add to Cart
Thermal Shock Test Machine Environmental Testing Equipment
Description:
Thermal Shock Test Machine is divided into high temperature area, low temperature area and test area three parts, each area is a unique insulation structure, so doing hot and cold impact test. And by the degree of high temperatures and very low temperatures in a continuous environment can tolerate at the moment, that is, in the shortest time test their chemical or physical damage due to thermal expansion and contraction caused. Suitable objects include metal, plastic, rubber, electronics and other materials can be used as a basis for improvement of their products or reference
Fuctions
High-temperature impact test or low-temperature impact test, the maximum time is up to 9999 minutes, the most cycle time is up to 9999 times. The machine can be automatically or manually cycle the impact or selectively set the two areas or three areas to impact of hot and cold. It used binary cooling system that is very effectiveness for cooling, the cooling system is divided into the air-cooled and water-cooled. It also can be connected with a computer, but the record instrument is only for optional purchase. Color LCD touch-control operation interface with Chinese and English, easy to operate.
Thermal Shock Chambers Operating: pretreatment, initial testing, testing, recovery, and finally detected.
Features
•Meets MIL-STD 202F, Method 107G, Conditions A, B, C, and F
MIL-STD 883, Method 1010.7, Conditions A, B, C, and F
•Solid-state overtemperature / undertemeperature protection
•Electric open-air nichrome wire heater elements supported by
ceramic insulators
•Two open ended finned LN2 cooling coils
•Centrifugal type blower wheel with external mounted motor
•Pneumatically activated carriage transport system with up to
six stainless steel mesh product baskets
•Test chamber drain with Type 1/4" FPT connection
•Door switches for each chamber
Air Conditioning System
· the air control: forced ventilation circulation, balance thermostat method (BTC). This method not only refers to the case of the cooling system for continuous operation, the control system according to the temperature set point of the heater to control the output of the results by automatically calculating PID output, and ultimately achieve a dynamic equilibrium.
· the air circulating means: built between the air circulation fan duct and the long axis of stainless steel, the use of energy efficient refrigerators and regulation system, by effective and efficient heat exchange ventilator, to achieve the purpose of the temperature change. By adjustable air outlet adjusting bolt, thereby significantly improving the chamber temperature uniformity;
· the air cooling method: multi-stage diaphragm air heat exchanger.
· the air heating: Watkins quality nickel chrome electric heater.
Specifications:
System | Two-zone test by means of damper switching | |||||||
Three-zone chamber | ||||||||
Model | HD-E703-50A/HD-E703-50W | HD-E703-100A/HD-E703-100W | Customized | |||||
Performance | Test area | High temp. exposure range*1 | +60~ to +200°C | |||||
Low temp. exposure range*1 | -65to 0 °C | |||||||
Temp. fluctuation *2 | ±1.8°C | |||||||
Hot chamber | Pre-heat upper limit | +200°C | ||||||
Temp. heat up time*3 | Ambient temp. to +200°C within 30min | |||||||
Cold chamber | Pre-cool lower limit | -65°C | ||||||
Temp. pull down time*3 | Ambient temp. to -65°C within 70min | |||||||
Temp. recovery (2-zone) | Recovery conditions | Two-zone: High temp. exposure +125°C 30 min, Low temp. exposure -40°C 30 min; Specimen 6.5 kg (specimen basket 1.5kg) | ||||||
Temp. recovery time | Within 10 min. | |||||||
Construction | External material | Cold-rolled rust-proofed steel plate | ||||||
Test area material | SUS304 stainless steel | |||||||
Door*4 | Manually operated door with unlock button | |||||||
Heater | Strip wire heater | |||||||
Refrigeration unit | System*5 | Mechanical cascade refrigeration system | ||||||
Compressor | Hermetically sealed scroll compressor | |||||||
Expansion mechanism | Electronic expansion valve | |||||||
Refrigerant | High temp side:R404A, Low temp side R23 | |||||||
Cooler | Stainless steel welded plate heat exchanger | |||||||
Air circulator | Sirocco fan | |||||||
Damper driving unit | Air cylinder | |||||||
Fittings | Cable port with diameter 100mm on the left side (right side and tailor made diameter size are available as options), specimen power supply control terminal | |||||||
Inside dimensions (W x H x D) | 350 x 400 x 350 | 500 x 450 x 450 | Customized | |||||
Test area capacity | 50L | 100L | Customized | |||||
Test area load | 5 kg | 10 kg | Customized | |||||
Outside dimensions (W x H x D) | 1230 x 1830 x 1270 | 1380 x 1980 x 1370 | Customized | |||||
Weight | 800kg | 1100kg | N/A | |||||
Utility requirements
| Allowable ambient conditions | +5~30°C | ||||||
Power supply | AC380V, 50/60Hz, three phase , 30A | |||||||
Cooling water supply pressure*6 | 02~0.4Mpa | |||||||
Cooling water supply rate*6 | 8m³ /h | |||||||
Operating cooling water temp. range | +18 to 23 °C | |||||||
Noise Level | 70 dB or lower |
Notes
· If the high-temp exposure range lower limit + 60°C is required or the low temp exposure range lower limit -60°C, please select the “ambient-temperature exposure” option
· If the temp fluctuation need to below ±1.8°C please select the “Low temp fluctuation package”
· Temperature heat-up/pull down time are applicable only during independent chamber operation
· If the automatically operated sliding door required, please select the “Automatically door package”
· Air-cooled condenser / Water-cooled condenser both available
· Apply on water-cooled condenser only
Safety Devices :
1)Hot chamber overheat protection switch
2)Cold chamber overheat protection switch
3)Air circulator overload alarm
4)Refrigerator high/low pressure protector
5)Compressor temperature switch
6)Air pressure switch
7)Fuse
8)Water suspension relay ( water-cooled specification only)
9)Compressor circuit breaker
10)Heater circuit breaker
11)Test area overheat/overcool protector
12)Air purge valve
Daily Maintenance
· hot and cold shock me a long shutdown is not used regularly every half power, power time is not less than one hour, and related spare parts and testing equipment is functioning properly.
· hot and cold shock boxes should be cleaned regularly evaporator: cleanliness levels because the test is different, in the forced air circulation effect, will gather a lot of dust particles and other small objects on the evaporator should be cleaned regularly.
· low-temperature chamber circulation fan, condenser fan and clean balance correction: cleaning and evaporator is similar because of different working environment chamber, circulating fan, will gather a lot of dust and other small particles on the object condenser fan should regular cleaning.
· hot and cold shock box device To move preferably at Paddy ASHDOWN Lai instrumentation technician guidance, in order to avoid damage to the equipment, such as customer self relocation, must have a professional electrician before turning on power to confirm correct operation of the circuit, or will burned equipment related components.
Operation and settings simplified by the use of a touch-screen LCD display (instructions displayed on-screen). At-aglance confirmation of test patterns, test area temperatures, temperature cycles, and trend graph displays.
Setting | Interactive key input by touch panel |
Display | LCD (5.7 inches) |
Temperature control function | Test area: exposure temp. Hot chamber: pre-heating temp. Cold chamber: pre-cooling temp. |
PID control | |
Preset temperature range | High temperature: 60 to200’C Low temperature: -78 to 0’C |
Setting resolution | 1’C |
Input | Thermocouple type T (Copper/Copper-Nickel) |
Setting and indication ranges | Preset time: 0 min. to 99 hours and 59 min. Preset cycle: 1 to 9,999 cycles |
Accessory function | Timer preset Overheat/ overcool protection Power failure/ recovery selection Temperature recovery time setting Program memory Automatic power shut-off Programmed time display Test completion mode selection Trend graph Alarm history display Sensor calibration RS-232/ USB communication |
Our Services
If you face any problems in future during testing process we promise we will give you a reply within 48 hours and solution provide within 3 working days. We can offer operation video and English operation muanual. We can provide video-conference. If customers require on-site service, the transport and travel expense shall be borne by customer.
1. Pre-service
24 Hours online service for your consult.
Help choose right model,and a series of service,person,advise.
2. Middle service
--Give you best offer
--Provide discount for many sets order
--Do customer's request:
--Choose payment term you convienent.
--Promptly production and delivery,inform you in time.
--Can provide invoice value as you like to decrease your tax.
3. After sale service
--1 year warranty service and all life maintenance.
--Technical Egineer are avalible for oversea trainning.
--Free change for some parts
--Remote control technical consult
--Free installation DVD
--Maintenance plan
4,Commitment:
We will sign a letter of commitment while we sign the contract, which will improve your confidence to us.
5,Good Packaging:
Good Packaging: Simulation Animatronic Customer Triceratops are covered with air bubble film before put them into the wooden case, which not only has good shock absorption, impact resistance, heat sealing and also has the advantages of nontoxic, odorless, moisture corrosion, good transparency etc.