Hai Da Labtester

Haida International Equipment CO.,LTD

Manufacturer from China
Verified Supplier
11 Years
Home / Products / Lab Test Machines /

HPLC Gas Chromatography Testing Machine Used For Quantitative And Qualitative Analysis

Contact Now
Hai Da Labtester
Visit Website
City:dongguan
Province/State:guangdong
Country/Region:china
Contact Person:MissLisa
Contact Now

HPLC Gas Chromatography Testing Machine Used For Quantitative And Qualitative Analysis

Ask Latest Price
Brand Name :Haida
Model Number :HD-R827
Certification :ISO
Place of Origin :China
MOQ :1 set
Price :Negotiable
Payment Terms :L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash, escrow
Supply Ability :300 Sets per Month Haida
Delivery Time :20 days after order confirmed
Packaging Details :each set protected with resin fiber and PP film, then put into Strong wooden case with operation man
Product Nmae :gas chromatography
Program heating rate :0.1~120℃/min(Incremental 0.1℃)
Maximum operating temperature :450℃
Minimum detectable limit :≤2.5pgC/s [n-C16]
Dynamic linear range :≥107(±10%)
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

HPLC Gas Chromatography Testing Machine Used For Quantitative And Qualitative Analysis

Product Description:

Gas chromatograph is used for quantitative and qualitative analysis to determine the physical and chemical constants such as the distribution coefficient, activity coefficient, molecular weight and surface area of the sample in the fixed phase. An instrument for analyzing the components of a mixed gas.

Column temperature Box
Furnace Size 28×30×18cm
Temperature control Range Above room temperature5℃~450℃;Using liquid nitrogen cold traps:-80℃~400℃;Using dry ice traps:-55℃~400℃
Temperature setting accuracy 0.1℃
Maximum program heating rate 120℃/min
Maximum once method run time 999.99min
Program temperature maximum order 7 stages
Program heating rate 0.1~120℃/min(Incremental 0.1℃)
Operation Column loss compensation (dual channel)
Heating Zone
6 independent control Heating zone control (excluding furnace temperature, two inlet, two detectors, two auxiliary heating area auxiliary heating zone maximum operating temperature )
300℃
Detectors
Hydrogen Flame Ionization detector FID
Maximum operating temperature 450℃
Minimum detectable limit ≤2.5pgC/s [n-C16]
Dynamic linear range ≥107(±10%)
Data acquisition frequency The highest: 100Hz
Thermal conductivity cell detector TCD
Maximum operating temperature 400℃
Minimum detectable limit <400pg C3H8/ml(He)
Dynamic linear range 105(±5%)
data acquisition frequency The highest: 100Hz
Flame photometric detector FPD
Maximum operating temperature 250℃
Minimum detectable limit <4pgC/sec,<1pg P/sec
Selective 105gS/gC,106gP/gC
Dynamic linear Range >103S,>104P
Electronic Capture Detector ECD
Maximum operating temperature 400℃
Detector compensation Gas Type 5% Methane/Argon or nitrogen
Minimum detectable limit <0.01Ppg/s lindane
Dynamic linear range >5×1055
data acquisition frequency Max 100Hz
Radioactive sources <12mCi 63Ni
Nitrogen and phosphorus detectors NPD
Maximum operating temperature 450℃
Minimum check out limit <0.2 pg N/sec,<0.2 pg P/sec
Dynamic linear Range 105N,105P
Minimum detection limit <0.3pg C/Sec
The above detectors are suitable for filling column and capillary column
Optional configuration
Anti-control software Automatic Feed b6891n

The table parameters is for the company Standard Model parameters, we support customer customization parameters

Advanced Power Distribution Management shunt

A 3000 watt UPS can provide 10 units of normal power 2250 watts/set of GC stable working power supply

Automatic Feed

8-bit automatic injection device (optional Agilent 7683/7693 liquid automatic injection)

With Automatic online detection function

Precision temperature control of the heating furnace

Furnace internal control accuracy less than 0.01°c

The temperature difference between the internal points is not more than the °c

Rapid heating and cooling, the highest program heating speed: 120℃/min, balance time 10 seconds, cooling time 300°c~50°c 6 minutes Absolute control of the temperature accuracy (with the actual temperature difference is less than 0.3C)

HPLC Gas Chromatography Testing Machine Used For Quantitative And Qualitative Analysis

Why Choose Us?

1. Considerate Service Different countries plugs, manually change the-voltage from 110V to 220V, insurance indicator.

2. Excellent After sale Service:

18 months warranty. Besides, we can help you to repair your problem controller freely, even it's not from our factory. What you need to do is to send us the controller.

3. Commitment:

We will sign a letter of commitment while we sign the contract, which will improve your confidence to us.

4. Good Packaging:

Simulation Animatronic Customer Triceratops are covered with air bubble film before put them into the wooden case, which not only has good shock absorption, impact resistance, heat sealing and also has the advantages of nontoxic, odorless, moisture corrosion, good transparency etc.

Inquiry Cart 0